Gondola amusement ride continues to rotate - passengers unable to disembark

Reference number
II-888382-2019 (#14664)

Location: Vancouver

Regulated industry sector: Amusement Devices - Amusement ride

Impact

Injury
Qty injuries:2
Injury description: Headache, dizziness, some nausea.
Injury rating: Insignificant

Damage
Damage description: No damage
Damage rating: None
Incident rating: Insignificant

Incident overview

During the ride cycle, the gondola rotation did not come to a stop in the horizontal position, passengers were unable to disembark the spinning ride until an emergency stop was initiated by maintenance personnel, who had been alerted by the ride operators, through dispatch.

Investigation Conclusions

Site, system and components

Up to 2 people sit in one of the twenty gondola cars, which are arranged in a circle, and loaded with passengers, while the ride frame is in a horizontal position. At start, the ride moves in a clockwise direction on the horizontal plane and then a hydraulically operated arm raises the ride frame, so it is at an almost vertical plane for a specific period of time.

The ride frame is then lowered back hydraulically to the horizontal plane, where the ride comes to a complete stop upon actuation of hydraulic arm position proximity switch (5B6) and passengers disembark.

Failure scenario(s)

· During the incident ride cycle, the cam that would normally actuate the proximity switch to stop the rotation at the return to horizontal position did not actuate the proximity switch.

Facts and evidence

· Mounting plate for the proximity switch (5B6) was found to be loose upon physical inspection, the proximity switch was sitting below the reach of the hydraulic arm actuator cam.

· According to electrical maintenance staff, no maintenance had been conducted on the proximity switches, including inspection, since the hydraulic rebuild conducted by the manufacturer in 2017.

· It is unknown if the measurements for the setup of the proximity switch (5B6) and hydraulic arm actuator cam were within tolerances specified by the manufacturer.

· Upon the return of the hydraulic arm to the horizontal position, the ride continued to rotate until an emergency stop button was depressed by staff.

Causes and contributing factors

It is highly likely that the loose mounting plate for the proximity switch (5B6), permitted the actuator cam on the hydraulic arm to miss the proximity switch (5B6), allowing the ride to continue to rotate in the horizontal position, until an emergency stop was depressed.

It is likely that the mounting plate became loose due to vibrations during operation.

Proximity switch rack

Proximity switch rack, and base of hydraulic arm with actuator cam(s)

Proximity switch rack 5B6

Proximity switch 5B6, proximity switch bolted mounting plate, hydraulic arm actuator cam.

Technical drawing of relationship between proximity switches and actuator cams.

Technical drawing of relationship between proximity switches and actuator cams.

Attachment Size
f 14664-888382 R 2020-FE-12.pdf 448.01 KB