8.7.2.1
|
x
|
Hoistway Enclosure
|
major
|
major
|
|
|
8.7.2.1.1
|
|
Hoistway Enclosure Walls
|
minor
|
|
|
|
8.7.2.1.2
|
|
Addition of Elevator to Existing Hoistway
|
|
new
|
|
|
8.7.2.1.3
|
x
|
Construction at Top of Hoistway
|
minor
|
|
|
|
8.7.2.1.4
|
x
|
Construction at Bottom of Hoistway
|
minor
|
|
|
|
8.7.2.1.5
|
|
Control of Smoke and Hot Gases
|
minor
|
minor
|
|
|
8.7.2.2.1
|
x
|
Pits
|
major
|
major
|
|
|
8.7.2.2.1
|
|
Pit Drains (requires engineer letter for conformance to 2.2.2.5)
|
minor
|
minor
|
|
|
8.7.2.2.1
|
|
Pit Guards
|
minor
|
minor
|
|
|
8.7.2.2.1
|
x
|
Pit Access (including ladders and access doors)
|
|
minor
|
|
|
8.7.2.2.1
|
|
Pit Illumination
|
|
minor
|
|
|
8.7.2.2.1
|
|
Pit Stop Switches
|
|
minor
|
|
|
8.7.2.2.1
|
x
|
Pit Depth
|
minor
|
|
|
|
8.7.2.2.1
|
|
Access to Underside of Car
|
minor
|
minor
|
|
|
8.7.2.2.2
|
|
Addition of Pit Sump
|
|
minor
|
|
|
8.7.2.3
|
|
Location and Guarding of Counterweights
|
minor
|
minor
|
|
|
8.7.2.4
|
x
|
Vertical Car and Counterweight Clearances and Runbys
|
minor
|
|
|
|
8.7.2.5
|
x
|
Horizontal car and counterweight clearances
|
minor
|
|
|
|
8.7.2.7
|
|
Machinery and sheave beams, supports and foundations
|
8.7.2.7.1
|
x
|
Enclosure (new construction)
|
major
|
|
|
|
8.7.2.7.2
|
|
Means of access
|
minor
|
minor
|
|
|
8.7.2.7.3
|
|
Access and door openings
|
minor
|
minor
|
|
|
8.7.2.7.4
|
|
headroom
|
minor
|
minor
|
|
|
8.7.2.7.5
|
|
Window and skylights
|
minor
|
minor
|
|
|
8.7.2.7.6
|
|
lighting
|
minor
|
minor
|
|
|
8.7.2.7.7
|
|
ventilation
|
minor
|
minor
|
|
|
8.7.2.8
|
|
Electrical equipment, wiring, pipes and ducts in H/W and machine rooms
|
8.7.2.8
|
|
Installation of new or altered electrical equipment, wiring, raceways, cables, pipes, ducts. (Includes HVAC and monitoring/video equipment)
|
minor
|
minor
|
|
|
8.7.2.9
|
x
|
Machinery and sheave beams, supports and foundations
|
major
|
major
|
|
|
8.7.2.10
|
|
Entrance and hoistway openings
|
8.7.2.10.1(a)
|
x
|
General requirements (new entrances)
|
major
|
major
|
|
|
8.7.2.10.1 (b)
|
x
|
New entrances with existing entrances
|
major
|
major
|
|
|
8.7.2.10.1(c)
|
x
|
Alteration H/W entrance
|
major
|
major
|
|
minor
|
8.7.2.10.1 (d)
|
x
|
Emergency doors
|
minor
|
major
|
|
minor
|
8.7.2.10.1 (e)
|
x
|
Access openings for cleaning
|
major
|
major
|
|
minor
|
8.7.2.10.2
|
x
|
Horizontal slide-type entrance
|
major
|
major
|
|
minor
|
8.7.2.10.3
|
x
|
Vertical slide-type entrance
|
major
|
major
|
|
minor
|
8.7.2.10.4
|
x
|
Swing-type entrances
|
major
|
major
|
|
minor
|
8.7.2.11
|
|
Hoistway door locking devices, access switches, and parking devices
|
8.7.2.11.1
|
x
|
Interlocks
|
minor
|
major
|
|
minor
|
8.7.2.11.2
|
x
|
Mechanical lock and contacts
|
minor
|
major
|
|
Minor
|
8.7.2.11.3
|
|
Parking devices
|
minor
|
minor
|
|
minor
|
8.7.2.11.4
|
|
Access switches and unlocking devices
|
8.7.2.11.4 (a)
|
|
Unlocking devices
|
minor
|
minor
|
|
|
8.7.2.11.4 (b)
|
x
|
Access switches
|
|
minor
|
|
|
8.7.2.11.5
|
|
Restricted opening of hoistway doors or car doors of passenger elevators (restrictors)
|
minor
|
minor
|
|
minor
|
8.7.2.12
|
x
|
Power operation of hoistway doors
|
minor
|
minor
|
|
minor
|
8.7.2.12
|
x
|
Replacement of door operator
|
minor
|
|
|
minor
|
8.7.2.13
|
x
|
Door reopening device (requires inspection when alteration includes alteration to door operator)
|
minor
|
major
|
|
minor
|
8.7.2.14
|
|
Car enclosures, car doors and gates and car illumination
|
8.7.2.14.1
|
x
|
New car enclosure
|
major
|
|
|
|
8.7.2.14.2
|
|
Alteration to existing car enclosure
|
minor
|
minor
|
|
|
8.7.2.14.2(b)
|
|
Top emergency exit
|
minor
|
minor
|
|
minor
|
8.7.2.14.2(c)
|
|
Installation of glass
|
|
minor
|
|
|
8.7.2.14.2(d)
|
|
Equipment added to car
|
|
minor
|
|
|
8.7.2.14.2.(h)
|
x
|
Addition of partitions to car enclosure
|
major
|
major
|
|
|
8.7.2.14.2(i)
|
x
|
Addition of car door or gate to existing elevator car
|
|
major
|
|
|
8.7.2.14.4
|
|
Other car enclosure alterations not specified in 8.7.2.14.2
|
|
minor
|
|
|
8.7.2.14.5.1
|
|
Addition of car top railing
|
|
minor
|
|
|
8.7.2.14.5.2
|
x
|
Addition of car top railing
|
|
major
|
|
|
8.7.2.15.1
|
x
|
Car frames and platforms
|
major
|
major
|
|
|
8.7.2.15.2
|
|
Increase or decrease in deadweight of car <5%
|
minor
|
minor
|
|
|
8.7.2.15.2
|
x
|
Increase or decrease the sum of deadweight and rated load by 5%
|
major
|
|
|
|
8.7.2.16
|
|
Capacity, loading, and classification
|
8.7.2.16.1
|
x
|
Change in type of service
|
major
|
|
|
|
8.7.2.16.2
|
x
|
Change in class of loading
|
major
|
|
|
|
8.7.2.16.3
|
x
|
Carrying of passengers on freight elevators
|
major
|
|
|
|
8.7.2.16.4
|
x
|
Increase in rated load
|
major
|
|
|
|
8.7.2.17
|
|
Change in rise or rated speed
|
8.7.2.17.1
|
x
|
Increase or decrease in rise
|
major
|
|
|
|
8.7.2.17.2
|
x
|
Increase in rated speed
|
major
|
|
|
|
8.7.2.17.2 (a)
|
x
|
Increase in rated speed of winding drum as specified in 8.7.2.17.2(c)
|
major
|
|
|
|
8.7.2.17.2 (b)
|
x
|
Increase in rated speed
|
major
|
|
|
|
8.7.2.17.2.(c)
|
|
Increase in speed not exceeding 10% and .20 m/s as specified in 8.7.2.17.2(c)
|
minor
|
|
|
|
8.7.2.17.3
|
x
|
Decrease in rated speed
|
major
|
|
|
|
8.7.2.18
|
|
Car and counterweight safeties
|
8.7.2.18.1
|
x
|
New car safeties
|
|
major
|
|
major
|
8.7.2.18.2
|
x
|
New counterweight safeties
|
|
major
|
|
major
|
8.7.2.18.3
|
x
|
Existing car safeties
|
major
|
|
|
major
|
8.7.2.18.4
|
x
|
Existing counterweight safeties
|
major
|
|
|
major
|
8.7.2.19
|
|
Speed governors and governor ropes
|
8.7.2.19
|
x
|
New or altered speed governor
|
major
|
major
|
|
major
|
8.7.2.19
|
|
Governor rope (different material or construction)
|
minor
|
|
|
minor
|
8.7.2.20
|
x
|
Ascending car overspeed and unintended car movement protection
|
major
|
major
|
|
major
|
8.7.2.21
|
|
Suspension ropes and their connections
|
8.7.2.21.1
|
x
|
Change in suspension members
|
major
|
major
|
|
|
8.7.2.21.2
|
|
Addition of suspension member equalizers
|
minor
|
minor
|
|
|
8.7.2.21.3
|
|
Addition of auxiliary rope suspension member-fastening devices
|
|
minor
|
|
|
8.7.2.21.4
|
x
|
Suspension means monitoring and protection
|
minor
|
minor
|
|
|
8.7.2.22
|
x
|
Counterweights
|
major
|
major
|
|
|
8.7.2.23
|
|
Car and counterweight buffers and bumpers
|
major
|
|
|
major
|
8.7.2.24
|
x
|
Guide rails, supports and fastenings
(Alteration or increase of stress >5%)
|
major
|
major
|
|
|
8.7.2.25
|
|
Driving machines and sheaves
|
8.7.2.25.1(a)
|
x
|
Alterations to driving machines and sheaves (part of an alteration)
|
major
|
major
|
major
|
major
|
8.7.2.25.1 (b)
|
x
|
Alteration to driving machines and sheaves (components)
|
major
|
major
|
|
minor
|
8.7.2.25.1(c)
|
|
Alteration to driving machines and sheaves (change in driving machine sheave)
|
|
|
minor
|
minor
|
8.7.2.25.2
|
x
|
Change in location of driving machine
|
major
|
|
|
|
8.7.2.26
|
|
Terminal stopping devices
|
minor
|
minor
|
|
|
8.7.2.27
|
|
Operating devices and control equipment
|
8.7.2.27.1
|
x
|
Inspection operation
|
minor
|
minor
|
|
minor
|
8.7.2.27.1
|
x
|
Inspection operation with open door circuits
|
minor
|
minor
|
|
|
8.7.2.27.2
|
|
Car leveling or truck zoning device
|
minor
|
minor
|
|
|
8.7.2.27.3
|
x
|
Change in power supply
|
major
|
|
|
|
8.7.2.27.4
|
x
|
Controllers
|
major
|
|
major
|
major
|
8.7.2.27.4(d)
|
x
|
Door controller (installation or alteration)
|
minor
|
|
|
minor
|
8.7.2.27.4(e)
|
x
|
Controller for emergency or standby power or FEO
|
minor
|
major
|
|
minor
|
8.7.2.27.5
|
x
|
Change in type of motion control (see directive D-L4-100311 2)
|
major
|
|
|
|
8.7.2.27.6
|
x
|
Change in type of operational control (see directive D-L4-100311 2)
|
major
|
|
|
|
8.7.2.27.7
|
|
In-car stop switch
|
minor
|
|
|
|
8.7.2.27.8
|
x
|
Electrical protective devices
|
major
|
major
|
|
minor
|
8.7.2.27.9
|
|
Door monitoring system
|
minor
|
minor
|
|
|
8.7.2.28(a)
|
x
|
Emergency operation and signaling devices (emergency signaling devices)
|
minor
|
minor
|
|
|
8.7.2.28(b)
|
x
|
Emergency operation and signaling devices (emergency or standby power)
|
minor
|
minor
|
|
minor
|
8.7.2.28(c)
|
x
|
Emergency operation and signaling devices (FEO)
|
minor
|
minor
|
|
|
8.7.2.28(d)
|
x
|
Emergency operation and signaling devices (addition of elevator to group)
|
minor
|
minor
|
|
|