Notice of Railway Works Guidelines for Heritage Railways

Persona

Technologies

Technologies

SHORT TITLE

1. These Guidelines may be cited as the Notice of Railway Works Guidelines.

INTERPRETATION

2. In these Guidelines, “municipality” means a municipality listed in Part 1 section 5 of the Canadian  Almanac and Directory, published by Copp Clark Pitman Limited, Toronto, Ontario, as amended from time to time.

PRESCRIBED KINDS OF WORKS

3. For the purposes of subsection 8(1) of the adopted provisions from the Railway Safety Act  (Canada), the following are prescribed as railway works of a kind for which notice shall be given:

(a) the construction or alteration of a line of railway involving the acquisition of land in addition to land on which an existing line of railway is situated;

(b) the construction or alteration in a municipality of railway bridges and culverts having an overall span greater than six metres and railway tunnels;

(c) the construction or alteration of structures located above or below a line of railway by a party other than a railway company, but excluding a mine or an oil or gas well;

(d) the construction or alteration of road crossings for public use, including the installation or alteration of road crossing warning systems, but excluding the installation or alteration of road crossing signs; and

(e) the construction or alteration of any line works that may affect drainage on land adjoining the land on which a line of railway is situated.

TIME AND CONTENT OF NOTICE

4. The notice referred to in section 3 shall

(a) be given at least 60 days before the proposed date of commencement of the proposed railway works;

(b) set out the period, not less than 60 days, during which objections, pursuant to subsection

8(2) of the adopted provisions from the Railway Safety Act (Canada), may be filed; and

(c) contain the following information, namely,

(i) a drawing showing the location of the proposed works,

(ii) a description of the proposed works with general plans, including elevations of proposed structures,

(iii) a description of any impact that the proposed works may have on the safety of persons and property, and

(iv) the proposed date of commencement and the projected time for completion of the proposed works.

PERSONS TO WHOM NOTICE IS TO BE GIVEN

5. (1) A notice referred to in section 3 shall be given

(a) in the case of a railway company proposing to construct or alter line works, to the municipality, or municipalities, in which the line works will be or are located and to any owner of land immediately abutting land on which the line works are situated;

(b) in the case of any party proposing to construct a road crossing, excluding the installation of a road crossing warning system, to the following, namely,

(i) the railway company whose line is to be crossed,

(ii) the municipality in which the crossing works are to be located,

(iii) the authority having responsibility for the road in question, and

(iv) any owner of land immediately abutting land on which the crossing works are situated; and

(c) in the case of any party proposing to alter a road crossing or to install or alter a road crossing warning system, to the following, namely,

(i) the railway company whose line is crossed,

(ii) the municipality in which the crossing works are located, and

(iii) the authority having responsibility for the road in question.

(2) A copy of a notice referred to in subsection (1) shall be sent forthwith to the Railway Safety Manager of the British Columbia Safety Authority