Design Registration

We are experiencing delays in processing design registration applications, including expedited services, due to capacity constraints and a significantly higher than normal volume of applications.  

Design Registration

We are experiencing delays in processing design registration applications, including expedited services, due to capacity constraints and a significantly higher than normal volume of applications.  

Detached children's power train coasts downhill on deviated track with rider in tow

Incident Investigation

Detached children's power train coasts downhill on deviated track with rider in tow

May 25, 2018

Amusement Devices

Reference Number:

II-711928-2018 (7781)



Incident overview

It was reported to Technical Safety BC that a retaining clip (“ R” clip) fell out of its intended position allowing the Passenger Carrying Unit ( PCU) to detach from the rides power train. The now free PCU coasted downhill, and was able to leave the ride track. The PCU and its rider came to rest against a ride fence at the bottom of the ride track hill.

Regulated industry sector

Amusement Ride

Location

Ladner, BC

Investigation conclusions

Site, system and components

The individual PCU’s are connected together with hitches that a fastened with a retaining clip known in the industry as a “R” clip. The PCU train is pulled along the track by an electric motor at the front of the train. The ride track has a hill incorporated to it as a ride feature. This ride is designed for small children.

Failure scenario(s)

During the assembly of the ride, ride erection personnel inserted an undersized retaining clip into the hitch of the PCU. Pre-operational inspection failed to identify this undersized part. During operation of the ride forces on the undersized clip caused the retaining clip to bend. The vibration and motion at the hitch caused the retaining clip to eventually come free from its intended position allowing the PCU to separate from the train.

Facts and evidence

  • A signed “Daily Maintenance Checklist” had been completed.
  • A signed “Set up Inspection Checklist” had been completed.
  • A bent or deformed “R” clip was found at the PCU dislocation point.
  • An undersized “R” clip was installed, based on the receiver hole size on the retaining pin.
  • See attached photos from site investigation.
  • Operator confirmed with the manufacturer the correct size of retaining clip.
  • The confirmed OEM retaining clip was of a larger dimension than the one evaluated at the site.

Causes and contributing factors

It is highly likely that the incorrect size of the retaining clip resulted in the separation of the PCU and allowed the resultant collision of the PCU with ride fence to occur. It is likely that either the device was not inspected or an incomplete inspection of the device was performed prior to the operation of the device. A lack of knowledge by Maintenance/ Operations personnel may have been a contributing factor. Inadequate supervision may also have been a contributing factor.

Impact

  • Injury
    • Qty injuries: 1
    • Injury description: One person was reported to be shaken up by the event
    • Injury rating: None
  • Damage
    • Damage description: An Undersized “R” clip became bent and deformed, and was forced out of the hole on the retaining pin.

A receptacle and surge protected power strip were destroyed in a fire located in the bedroom of a residential unit in a multi-family building. Minor fire and smoke damage to the bedroom wall.

    • Damage rating: Major

Incident rating

Major

 

Attachment
Size
451.58 KB