Elevator Braking Resistor Bank Overheats, Resulting in Fire

Incident Investigation

Elevator Braking Resistor Bank Overheats, Resulting in Fire

October 3, 2022

Elevating Devices

Reference Number:

#II-1447197-2022 (#30043)



Location: New Westminster, BC

Elevating devices - Elevator

Incident Overview

An elevator braking resistor bank overheated due to exposure to continuous power. The transistor intended to limit power to the braking resistor bank failed causing the overheating condition and resulting in fire.

Attachment