Gondola Cabin Fall After Hanger Arm Failure

Incident Investigation

Gondola Cabin Fall After Hanger Arm Failure

March 10, 2025

Passenger Ropeways

Reference Number:

II-1879030-2025 (# 56794)



Location: Golden

Regulated industry sector: Passenger Ropeways

Incident overview

A hanger arm on the Golden Eagle Express (GEE) gondola failed just after leaving the bottom station, causing the cabin to detach and fall approximately 1 to 1.5 m to the ground. There were eight passengers inside and only minor injuries were reported.  Technical Safety BC issued a report detailing the cause and contributing factors to the incident including 3 recommendations to industry to further enhance gondola safety in BC. 

Attachment