Improper Aluminum Wiring in Hot Tub Installation Causes Control Box Fire and Power Loss in Home

Incident Investigation

Improper Aluminum Wiring in Hot Tub Installation Causes Control Box Fire and Power Loss in Home

March 10, 2024

Electrical

Reference Number:

II-1703922-2024 (#45823)



Location: Delta

Regulated industry sector: Electrical - Low voltage electrical system (30 to 1000V) 

Incident overview

At a single-family home, an electrical hot tub control box burnt causing loss of power to the home. The hot tub was installed in 2021 with a #6 AWG aluminum armoured feeder cable (ACWU), instead of the manufacturer required #6AWG copper conductors. The aluminum conductors resulted in high resistance connections that ignited the box when the hot tub was operating. 

Attachment
Size