Six common barbecue dangers – and how to avoid them

Before you fire up the grill this spring, take some basic safety precautions! Each year, Technical Safety BC receives reports of incidents resulting from gas barbecues. The most dangerous time to use a grill is at the beginning of the barbecue season, after equipment hasn’t been used for a while.  Here are six common barbecue safety mistakes – and how to avoid them.

1. Failing to Follow Manufacturer’s Instructions
Having a new barbecue is exciting, but don’t rush to fire it up without reading and understanding the manufacturer’s operating and installation instructions. Each barbecue is slightly different so don’t assume you know how to operate it. Carefully review the instructions and follow any cleaning and maintenance requirements.

2. Dirty or Poorly Maintained BBQs
If you haven’t used your barbecue for a while or it has been in storage, check the burner for any obstructions and make sure the gas supply hose is in good condition. If you spot any cracks or abrasions, have it replaced. Once you have your propane cylinder or gas supply hooked up, check the gas connections for leaks using a solution of 50% dish detergent and 50% water. Brush the solution onto the connections with a paint brush and watch for any bubbles to appear, indicating a gas leak. If required, tighten up the connections again and re-test until no bubbles appear. If a leak cannot be stopped, do not attempt to light the grill. Never use matches or lighters to check for leaks.

3. Locating a BBQ Near Flammable Objects
Barbecues should ideally be located on a flat, sturdy, non-combustible surface such as concrete or patio stones. To eliminate the chance of a fire spreading beyond the barbecue, maintain the minimum clearance that is shown on the appliance nameplate. Be sure to allow your BBQ to cool off completely before putting on the barbecue cover.

4. Failing to Have Licensed Contractors Doing Gas Work
Having a built in barbecue installed? Built in BBQs require a gas installation permit, portable BBQs do not. Remember that installation of gas piping or a built-in BBQ is regulated work and must be done by a licensed contractor. Make sure your contractor is registered with Technical Safety BC, and has pulled the appropriate permits for the work before they get started.

5. Using Barbecues in Enclosed Areas
Barbecuing produces carbon monoxide (CO) which can be harmful and deadly. For this reason, never use a barbecue in any enclosed or partially enclosed area such as a garage or porch. Keep it in a well-ventilated area, away from any open windows or doors to avoid carbon monoxide from entering your home.

6. Neglected Propane Cylinders
All propane cylinders must be re-certified every 10 years or they cannot be refilled. Check the date on the cylinder and its condition. If it’s dented or rusty, have it checked by your gas supplier before filling. Also, if you are transporting your propane cylinder, keep it secure, upright and in a well ventilated space at all times.

For more information about BBQ and propane safety, view our Grilling Safety page.

About Technical Safety BC
Technical Safety BC is an independent, self-funded organization mandated to oversee the safe installation and operation of technical systems and equipment. In addition to issuing permits, licences and certificates, it works with industry to reduce safety risks through assessment, education and outreach, enforcement, and research.

-30- 

For more information, please contact:

Media Relations
Technical Safety BC
778-396-2164
media@technicalsafetybc.ca

Was this page useful to you?
Share article on
FacebookTwitterLinkedinEmail